This site uses cookies for functional purposes. To continue please read and agree to our Data Privacy.

By closing this message, you consent to our use of cookies on this device.

 

 

 

Welcome to the PLCnext Community

This website is built to help you getting started with your PLCnext Control and PLCnext Engineer
Registered users are invited to use the Forum and the Makers Blog to share their experiences and ideas with the community and our product specialists.

 

 

 

 


Available now: New Firmware 2019.6

fw2019.6With Firmware 2019.6 , we introduce new and thrilling features in PLCnext Technology - again.

The most interesting thing is our innovative real-time, task-synchronous DataLogger. Record energy data or process steps in next to no time! With the "Record on Change" function, you can keep track which states have changed and when they did. And this all with minimum effort and without programming on your side.

In addition, the embedded OPC UA Server supports Historical Access, so you can access all data recorded by the DataLogger at any time. Read more details on GitHub, and find a config file there.

Firmware 2019.6 also supports MRP Client functions with Profinet devices: The Media Redundancy Protocol (MRP), standardized as IEC 62439-2, allows rings of Ethernet switches to overcome any single failure within a recovery time much faster than achievable with the Spanning Tree Protocol. This feature is highly useful and suitable for most Industrial Ethernet applications.

All the new features will be thrilling to explore, and so we added enhanced performance to the real-time execution as well.

What's new?

We need you

My Post 25

Dear PLCnext Community: WE NEED YOU!

You are a part of the PLCnext Community? You use the forum, Makers Blog or the knowledge base regularly? Well, then we are looking for you because we would like to feature you in our Phoenix Contact magazine.

Please let us know if you would like to be interviewed and tell us about your experiences with PLCnext Technology and the PLCnext Community. We will then contact you and talk about the details.

Comment our post here (make sure you are logged in) and give us permission to contact you.

 

Talk to you soon,

Your PLCnext Team

 

Available now: New Firmware 2019.6

fw2019.6With Firmware 2019.6 , we introduce new and thrilling features in PLCnext Technology - again.

The most interesting thing is our innovative real-time, task-synchronous DataLogger. Record energy data or process steps in next to no time! With the "Record on Change" function, you can keep track which states have changed and when they did. And this all with minimum effort and without programming on your side.

In addition, the embedded OPC UA Server supports Historical Access, so you can access all data recorded by the DataLogger at any time. Read more details on GitHub, and find a config file there.

Firmware 2019.6 also supports MRP Client functions with Profinet devices: The Media Redundancy Protocol (MRP), standardized as IEC 62439-2, allows rings of Ethernet switches to overcome any single failure within a recovery time much faster than achievable with the Spanning Tree Protocol. This feature is highly useful and suitable for most Industrial Ethernet applications.

All the new features will be thrilling to explore, and so we added enhanced performance to the real-time execution as well.

New Video: PLCnext Store - install unexpected possibilities

My Post

A woman works in a bar and has to walk home in the dark every night. Her colleague likes her and knows somebody at the municipal utility but what does all of that have to do with the PLCnext Store?... Watch this new video about the PLCnext Store now available on YouTube and find out.

Read more ...

Hannover Messe 2019: new releases

My Post 24

During the Hannover Messe 2019, we updated you about new, innovative products from Phoenix Contact through daily livestreams - two of them were about the PLCnext Store and the new PLCnext Control RFC 4072S. Watch the videos from our livestreams here...

Read more ...

Available now: New Firmware 2019.3

My Post 20The brand new Firmware 2019.3 is out now:

Use the Profinet Redundancy Layer (PRL) for Profinet devices in order to set up a PLCnext Control AXC F 2152 as an underlying device for the RFC 460R in a redundancy system.

The new dynamic bus configuration for the Axioline local bus allows you to configure the Axioline bus from the application* without having to manually assemble the bus structure beforehand. These and other new firmware features will #enhance your possibilities in PLCnext Technology - again.

The Inline adapter terminal AXC F IL ADAPT is supported by the firmware as well as the new PLCnext Store App types: the first Function Extensions and Runtime apps are now available.

* read, configure and start the Axioline bus using the Axioline RSC Service or the corresponding PLCnext Engineer Function Block - this is not related to the PLCnext Engineer feature "Read Axioline Bus"

PLCnext Technology on Instagram

PLCnext Instagram Phoenix Contact

Hi everyone,

there's good news: PLCnext Technology has found a new social media home on Instagram.  

www.instagram.com/plcnext

Be social

We want to strengthen the community. That means please subscribe, share, like, comment and tell all your friends, colleagues, family and - of course - dogs.

Hashtags #plcnext and #iamplcnext

With the hashtags #plcnext and #iamplcnext we want to make our community visible. So if you have an exciting posts about PLCnext Technology, please use these hashtags.

#plcnext #iamplcnext

The IXON Cloud Connector on the PLCnext Store is your gateway to remote access and Industrial IoT

ixon Header

Connecting PLCs to your web-based IIoT portal has never been easier. Manage, monitor and control your systems, and turn machine data into insights using advanced reporting and alarms with integrated IXON Cloud and connectivity.

Read more ...

CODESYS Control for PLCnext Technology

Codesys Control for plcnext sl

The PLCnext controller from Phoenix Contact can be programmed with the market-leading IEC 61131-3 tool CODESYS.

Watch the following video for further information.

Read more ...