This is my archive
How to set up the AXC F XT IB INTERBUS master Available from 2019.3 with AXC F 2152 or AXC F 3152 Requirements The AXC F XT IB is installed and the supply voltage is connected (see AXC F XT IB datasheet). Adding the AXC F XT IB INTERBUS master to your bus configuration Selecting the AXC F XT IB INTERBUS master Double-click the controller node in the… Read More
PLCnext Control hardware documentation For each PLCnext Control device or extension, there is a user manual or a data sheet available on the Phoenix Contact website. For your convenience, we’re making those PDF documents available for download here, too. Where there’s additional documentation mentioned, please refer to the respective product page on the Phoenix Contact website. Read More
How to set up the AXC F XT ETH 1TX module Available from 2019.0 LTS with AXC F 2152, and from 2021.0 LTS with AXC F 3152 AXC F 2152 or AXC F 3152 can be extended with an additional Ethernet interface using the AXC F XT ETH 1TX left-alignable Axioline F extension module. This topic shows how to integrate and configure the AXC F XT ETH 1TX. For further information, see Extensions and Hardware documentation. Installing the AXC F XT ETH 1TX Ethernet interface… Read More
Starting up the AXC F XT PB PROFIBUS® master Available from 2022.0 LTS for AXC F 2152 The AXC F XT PB PROFIBUS® master currently supports the PROFIBUS® DP/V0 mode. Requirements The AXC F XT PB is installed and the supply voltage is connected (see AXC F XT PB datasheet). Preparing your workbench The AXC F XT PB PROFIBUS® master can be started up with the following steps: Downloading and… Read More
Adding Inline modules by means of AXC F IL ADAPT Available from 2019.0 LTS with AXC F 2152, and from 2020.6 with AXC F 1152 and AXC F 3152 You can run an Inline station at a PLCnext Control. To do so, you need the right-alignable AXC F IL ADAPT Inline adapter terminal (item no. 1020304). For mounting and installation at the controller see the AXC F IL ADAPT data sheet. To configure the Inline station, proceed… Read More
Adding left-alignable AXC F XT modules You can connect one extension module to the left of the AXC F 2152 using the AXC BS L 2 bus base module, and two extensions to the left of the AXC F 3152 using the AXL F BS AXC 3X5X bus base module. In addition to the respective documentationfor each product, there are quick introductions available on how to integrate… Read More
Starting up the AXC F XT ML 1000 module Available from 2022.0 LTS for AXC F 3152 Requirements The AXC F XT ML 1000 is installed and the supply voltage is connected (see AXC F XT ML 1000 data sheet). A firmware version ≥ 2022.0 LTS is installed on the AXC F 3152. For the installation of some of the required components the AXC F 3152 must be connected to… Read More