Vulnerabilities and exposures for PLCnext Control AXC F 2000 EA

The following sections list the security vulnerabilities (CVEs) that have been resolved in the respective firmware release. For more information about the specified CVE numbers, see:

Information on the Phoenix Contact PSIRT can be found at https://www.phoenixcontact.com/psirt.

Firmware releases 2026.x

2026.0.5 LTS2026.0.5 LTS

Released on 2026-07-20

Gnutls

  • CVE-2026-42009

OpenSSL

  • CVE-2026-7383
  • CVE-2026-9076
  • CVE-2026-34180
  • CVE-2026-34182
  • CVE-2026-42766
  • CVE-2026-42767
  • CVE-2026-42770
  • CVE-2026-45445
  • CVE-2026-45446
  • CVE-2026-45447

Nginx

  • CVE-2026-1642
  • CVE-2026-9256

2026.0.4 LTS2026.0.4 LTS

 Released on 2026-06-30  

ACF

  • CVE-2025-41670

Curl

  • CVE-2026-1965
  • CVE-2026-3783
  • CVE-2026-3784
  • CVE-2026-4873
  • CVE-2026-5545
  • CVE-2026-5773
  • CVE-2026-6253
  • CVE-2026-6276
  • CVE-2026-6429
  • CVE-2026-7168

Expat

  • CVE-2026-45186

Gnutls

  • CVE-2026-3832
  • CVE-2026-3833
  • CVE-2026-33845
  • CVE-2026-42010

Glibc

  • CVE-2026-4046
  • CVE-2026-4437
  • CVE-2026-4438

Kernel

  • CVE-2026-31431
  • CVE-2026-43037
  • CVE-2026-43038
  • CVE-2026-43186
  • CVE-2026-43284
  • CVE-2026-46300

Libexpat

  • CVE-2026-32776
  • CVE-2026-32777
  • CVE-2026-32778
  • CVE-2026-41080

Libssh

  • CVE-2025-5987
  • CVE-2026-3731

Nghttp2

  • CVE-2026-27135

NTP

Via web-based Management service any parameters for the NTP/chrony configuration could be written to the configuration file and applied accordingly.

Openssh

Support of the obsolete “+ssh-rsa” algorithm has now been removed. In order to maintain compatibility with older clients, the algorithm was explicitly reactivated in previous updates, despite being communicated as removed.

  • CVE-2026-35385
  • CVE-2026-35386
  • CVE-2026-35387
  • CVE-2026-35388
  • CVE-2026-35414

OpenSSL

  • CVE-2026-28387
    CVE-2026-28388
    CVE-2026-28389
    CVE-2026-28390
    CVE-2026-31789
    CVE-2026-31790

Python

  • CVE-2025-12084
  • CVE-2025-13836
  • CVE-2025-13837

Remote Sync (rsync)

  • CVE-2026-29518
  • CVE-2026-41035
  • CVE-2026-43617
  • CVE-2026-43618
  • CVE-2026-43619
  • CVE-2026-43620
  • CVE-2026-45232

WBM: Backup & Restore

  • During decryption of an encrypted backup, a WBM alert containing internal security-related information was triggered when a user entered an incorrect password.
  • During backup creation it was possible to set an encryption password with the length of one character.