Security Profile: Uploading the certificate in the browser 

  • Log in to the WBM. 

    Return to topicHow do I get to the WBM again? Click here for more information... 

    Establishing a connection to the Web-based Management (WBM):

    • Open a web browser on your computer.
    • In the address field, enter the URL https://<IP-address-of-the-controller>/wbm,
      for example: https://192.168.1.10/wbm.

    For further information, see WBM.

  • Open the Security → Certificate Authentication page in the WBM. 
  • Open the Identity Stores tab. 
  • In the HTTPS-self-signed area, download the certificate you just generated by clicking the  button ("Download from controller to local pc") next to the certificate. 
  • Open your browser (Edge).
  • Open the Settings menu. 
     
  • Open the Privacy, search, and services tab .
  • In the Security section, click the Manage certificates button.

    ↪ A new window opens.
  • Open the Trusted root certificates tab. 
  • Click the Import... button.
    ↪ The "Certificate Import Wizard" opens.
  • Follow the instructions of the "Certificate Import Wizard". 
  • Select the certificate you want to import and click the Open button. 
  • Click the Next button.
  • Select Place all certificates in the following store and click the Browse... button. 
  • Set the certificate store option to Trusted root certificates and click the OK button. 
  • Click the Next button.
  • Click the Finish button.
  • If a warning note opens, read the warning note and in case you want to confirm it, click the Yes button. 
    ↪ The certificate was uploaded in the browser. 
  • Check the status of the certificate in your browser. 

 

 

 