Protection against physical access Protection against physical access is an important requirement for OT devices (component). Attackers may access the hardware and try to manipulate the firmware, configuration, or applications. IEC 62443 describes major attack vectors, like: non-operational transferring the component from the manufacturer to the… Read More
AXC F 1152 Note: For further information about the hardware, refer to the product documentation of this controller (item no. 1151412): User manual Product page The AXC F 1152 is approved for certified security based on a limited scope. The AXC F 1152 does not support left-alignable modules and therefore network segmentation is not… Read More
RFC 4072S Note: For further information about the hardware, refer to the product documentation of this controller (item no. 1051328): User manual Product page Risk of unauthorized access to devices The safety controller RFC 4072S has a touch screen display and is used with an external SD card. This makes… Read More
SD card encryption Note: Make sure that the Security Profile is activated before you start encrypting the SD card. Please also note the general information on handling encrypted SD cards in the main PLCnext Technology – Info Center. You can only use the following SD cards… Read More
Device certificates In this topic you can find out about current device certificates. For example, there is currently a new device certificate for the PLCnext Control devices, see the following screenshot: Further information can be found on the Phoenix Contact Device PKI website. • Published/reviewed: 2026-04-20 • Revision 022… Read More
AXC F XT SPLC 3000 (SPLC 3000) Note: The AXC F XT SPLC 3000 (SPLC 3000, item no. 1160157) is developed in compliance with the IEC 62443-4-1 process and meets the requirements of IEC 62443-4-2, as detailed in the security and safety hardening guidelines. Officially, the SPLC 3000 will be included in the forthcoming IACS Components PLCnext Control certificate for firmware 2026.0 LTS. Read More
AXC F 1252 Security context The AXC F 1252 can be used in various security contexts. Below are three examples of different security contexts. Decentralized control of an Axioline F station: Operation as PROFINET device: Operation as PROFINET controller: Connecting and operating elements The controller consists of the following components: … Read More
Updating the firmware Note: If the boot process failed five consecutive times then the inactive and the active boot partition will change their roles. This behavior has been implemented to keep the PLCnext Control device accessible even if the firmware update fails. The behavior can also occur when the boot… Read More
AXC F 3152 Note: For further information about the hardware, refer to the product documentation of this controller (item no. 1069208): User manual Product page There are different Ethernet and firewall configurations due to three Ethernet interfaces. Connecting and operating elements The controller consists of… Read More
BPC 9102S Note: For further information about the hardware, refer to the product documentation of this controller (item no. 1246285): User manual Product page Connecting and operating elements The controller consists of the following components: 1 BPC 9102S 2 BPC 9102 FAN KIT… Read More