This is my archive

Administration – Software update tab

Administration – Software update tab DaUM as a repository server is available from DaUM version 2025.6 (Windows® service) On the SOFTWARE UPDATE tab you can add and manage the update repositories.  The update repository is the place where the firmware files are located. You can add a new… Read More

Real-time DataLogger configuration

Real-time DataLogger configuration Available from firmware 2019.3 There are different ways available to set up and configure a DataLogger session: from firmware 2019.3: configuration based on an XML file from firmware 2020.6, additionally: via PLCnext Engineer via RSC IDataLoggerService2 (reading values, handling a session) Let’s see which way… Read More

Add software update package

Add software update package On the SOFTWARE tab you can manage and update PLCnext Engineer projects on your PLCnext Control. To do this, open PLCnext Engineer  and add the version information in your PLCnext Engineer project (see example screenshot below). Export the software package.  Upload the exported *.zip file in the Device and Update… Read More

Security notifications registered by the PLCnext Runtime System

Security notifications registered by the PLCnext Runtime System Available from 2022.0 LTS The following tables show the security-related notifications that are predefined in the PLCnext Runtime System and will be issued by the PLCnext Runtime System. Note: For non-security-related notifications, see Notifications by PLCnext Runtime. Compatibility Due to breaking changes… Read More

Redundancy in PLCnext Technology

Redundancy in PLCnext Technology In engineering, redundant systems are key for enhancing operational reliability: Critical components are intentionally duplicated (in safety-critical systems: triplicated) to provide a permanent backup or fail-safe to take over operations immediately in case the main component fails.  In PLCnext Technology, redundancy can be implemented… Read More

Notifications registered by the PLCnext Runtime System

Notifications registered by the PLCnext Runtime System The following tables show the notifications that are predefined in the PLCnext Runtime System and will be issued by the PLCnext Runtime System.  Note: For security-related notifications with firmware 2022.0 LTS or newer, see Security notifications of PLCnext Runtime. Compatibility The SenderName declarations have changed… Read More

Notification Manager

Notification Manager Use Case Notifications in PLCnext Technology are messages referring to special events. The Notification Manager enables sending and receiving notifications between components of a controller. Notifications can also transport user data (payload) which is information data without control or protocol information (no process data, no real-time… Read More

Reverse connect

Reverse connect To enable the devices to connect to the DaUM via reverse connect, you must first enable reverse connect and set the correct port via PLCnext Engineer. In PLCnext Engineer, click on the OPC UA node in the PLANT area.  Select the Server Settings editor.  In… Read More

Assets

Assets On this page you get an overview of all available assets in the system. An asset is the updatable software component, which is represented over the OPC UA® Server and can be updated. This can be, for example, a PLCnext Engineer project or an update for subordinate devices. Browse and organize your assets… Read More

Archive

Archive When an update is complete, you can review each step in the execution log and download a report of the update plan on the ARCHIVE tab.    • Published/reviewed: 2026-01-29  ☃  Revision 088 • … Read More