Secure by default: Activating PROFINET 

Secure by default: Activating PROFINET  A large port range is required for the use of PROFINET as the system automatically selects the required ports depending on the network configuration. To restrict access to the PROFINET interfaces, the IP addresses of the PROFINET devices must be configured so that… Read More

Secure by default: Installing apps

Secure by default: Installing apps Installing apps can compromise security Before installing an app, you must perform a risk analysis of the app and its impact on the security of the device and the application, taking into account the overall security context. In particular, investigate the following… Read More

Secure by default: Password complexity rules 

Secure by default: Password complexity rules  The password complexity rules are predefined and depend on the rights of each user. You may need to adjust the rule set to meet the needs of your application. Pre-defined rule sets With firmware 2022.0 LTS and 2023.0 LTS,  the “Admin Ruleset” and the “Default Ruleset”… Read More

Secure by default: Creating users 

Secure by default: Creating users  The Admin can only configure the system. All other activities must be performed by other users with other roles. You need at least a Security Engineer to access the security notifications, an Engineer to program in PLCnext Engineer and an Operator to operate an… Read More

Secure by default: Configuring Active Directory Connection 

Secure by default: Configuring Active Directory Connection  With PLCnext Technology you are able to connect Active Directory servers via LDAP.  For further information, refer to the topic LDAP configuration in the main PLCnext Technology ‑ Info Center.  Replacing the local user management with LDAP while maintaining IEC 62443‑4-2 compliance PLCnext Control‘s User Manager is… Read More

Secure by default: Checking the validity of passwords

Secure by default: Checking the validity of passwords Changing the default password After the admin has created a user account with password, you must change the default password. If you do not change the default password, you will receive appropriate warnings. You can change the user… Read More

Secure by default: Configuring authentication errors and sessions 

Secure by default: Configuring authentication errors and sessions  Session Configuration Log in to the WBM.  Return to topicHow do I get to the WBM again? Click here for more information…  Establishing a connection to the Web-based Management (WBM2): Open a web browser on your computer. Read More

Secure by default Guideline and security measures – an overview

Secure by default Guideline and security measures – an overview To achieve security in an automation system, a holistic approach is necessary. An adequate security concept must be drawn up that covers technologies used, the defined processes, and the people involved. Both technological and organizational measures must be taken… Read More

Secure by default: Use cases and security context 

Secure by default: Use cases and security context  PLCnext Technology is supporting different security use cases. There are PLCnext Control devices that are equipped with Security Profile and devices that are secure by default. Check which device you are using in the PLCnext Control topic. A secure by default PLCnext Technology device is an IEC 62443-4-1/4-2… Read More

Secure by default: Configuring the system time 

Secure by default: Configuring the system time  Centralized security logging only makes sense if all devices have a synchronized time. NTP is already supported today. TimeServer provides all devices with the same time base. For each device you have to configure which time server it should use. Read More