This is my archive
Adding left-alignable AXC F XT modules You can connect one extension module to the left of the AXC F 2152 using the AXC BS L 2 bus base module, and two extensions to the left of the AXC F 3152 using the AXL F BS AXC 3X5X bus base module. In addition to the respective documentationfor each product, there are quick introductions available on how to integrate… Read More
Product range The information in this Info Center is about the PLCnext Runtime System, which is the firmware on PLCnext Control devices. In addition, use cases with related hardware and software are described if useful in the course of a documented feature. Each PLCnext Control comes with its own hardware documentation, which can be a… Read More
Firmware releases Release strategy Each year comes a long-term support (LTS) release which will be supplied with security enhancement and bug fixes (if necessary). Each quarter follows a feature release with additional capabilities. Those feature releases always contain the former features in full, so you… Read More
Adding Inline modules by means of AXC F IL ADAPT Available from 2019.0 LTS with AXC F 2152, from 2020.6 with AXC F 3152* and from 2025.6.1 with AXC F 1252* (*HW 03 of the AXC F IL ADAPT needed) You can run an Inline station at a PLCnext Control. To do so, you need the right-alignable AXC F IL ADAPT Inline adapter terminal (item no. 1020304). For mounting and installation at the controller see the AXC F IL ADAPT data sheet. To… Read More
PLCnext Control extensions In this topic you see the main features of the available extensions and adapters to PLCnext Control devices. For a sneak peek into our further development and current activities, please refer to the Development roadmaps. You can use the following extension modules with Axioline F-based PLCnext Control (for example, AXC F 2152 or AXC F 3152)… Read More
PLCnext Control hardware documentation For installing and starting up a PLCnext Control device or extension, there is a user manual or a data sheet available on the Phoenix Contact website. For your convenience, we’re linking to those PDF documents for download here, too. Where there’s additional documentation mentioned, please refer to the respective product… Read More
Getting started with PLCnext Engineer Simulation Available for firmware 2022.0 LTS, 2023.0 LTS and 2025.0 in combination with PLCnext Engineer With PLCnext Engineer Simulation, you can execute many of the functions, components, and models in your automation project without having a PLCnext Control at hand. There are some restrictions still, and further development is being done. Nevertheless, with this approach it is easier to test… Read More
Starting up the AXC F XT ML 1000 module Available on AXC F 3152 with firmware 2022.0 LTS only Requirements The AXC F XT ML 1000 is installed and the supply voltage is connected (see AXC F XT ML 1000 data sheet). A firmware version 2022.0 LTS is installed on the AXC F 3152. Note: For controllers with firmware versions from 2022.6, use a container (e. g., docker) including… Read More
Starting up INTERBUS with physical addressing Available on AXC F 2152 and AXC F 3152 from firmware 2019.3, and PLCnext Engineer from 2019.3 Requirements The AXC F XT IB is installed and the supply voltage is connected (see AXC F XT IB data sheet). In PLCnext Engineer: A project has been created The IP settings have been configured A connection to the controller has been established Adding the AXC F XT IB to… Read More