This site uses cookies for functional purposes. To continue please read and agree to our Data Privacy.

By closing this message, you consent to our use of cookies on this device.

PLCnext Engineer - Features Overview

Print

For detailed information, click on the headline for the regarding section to unfold the features' table:


Controller PC Worx Engineer 7.2.x PLCnext Engineer 2019.0 LTS PLCnext Engineer 2019.3 PLCnext Engineer 2019.6
AXC F 1050  —   —   — 
AXC F 2152 ✔ (FW 1.x only)
RFC 4072S  —   — 

Feature PC Worx Engineer 7.2.x PLCnext Engineer 2019.0 LTS PLCnext Engineer 2019.3 PLCnext Engineer 2019.6
Support of multiple screens  —  Cross-function area Cross-function area Cross-function area
Systemfilter
Global cross references
Local cross references  — 
Recycle bin function
Mini Map "Bird view"  — 
Support of Multiple Instances  —   —   — 

Feature PC Worx Engineer 7.2.x PLCnext Engineer 2019.0 LTS PLCnext Engineer 2019.3 PLCnext Engineer 2019.6
Background compilation
and syntax check
Download change  — 
Structured Text (ST)
Function Block Diagram (FBD)
Ladder Diagram (LD)
Network orientated editor (NOLD)
Extended variable identifier  — 
Initialisation of
user-defined data types
 — 
Initialisation of
user-defined data instances
 — 
Copy POUs from libraries  —   —   — 


Object-orientated programming (OOP)

Feature PC Worx Engineer 7.2.x PLCnext Engineer 2019.0 LTS PLCnext Engineer 2019.3 PLCnext Engineer 2019.6
Methods for function blocks


SFC+ (Sequential Function Chart)

Feature PC Worx Engineer 7.2.x PLCnext Engineer 2019.0 LTS PLCnext Engineer 2019.3 PLCnext Engineer 2019.6
Basic functions
Interlocks  — 
Watchdog  — 
Type & Info struct  — 
Compact SFC function block representation  — 
Pre- and post-execution worksheet  — 

The first supported PLC is RFC 4072S (Part no. 1051328).

Feature PC Worx Engineer 7.2.x PLCnext Engineer 2019.0 LTS PLCnext Engineer 2019.3 PLCnext Engineer 2019.6
Profisafe  —   — 
Network granular CRC  —   — 
Signal path analysis  —   — 
Safe semantic analysis  —   — 
Functional Safety - User libraries  —   — 
Undo/Redo functionality in safety editor  —   —   — 

Feature PC Worx Engineer 7.2.x PLCnext Engineer 2019.0 LTS PLCnext Engineer 2019.3 PLCnext Engineer 2019.6
Basic forms and elements
Symbols
Symbols in symbol (one level)  —   — 
Animations
Actions - Execute an event
Actions - Multiple events  — 
Actions - Write value  —   — 
Search and replace in symbols and dynamics  — 
Import and export HMI Libraries  — 
Import pages from other projects  — 
Access IEC 61131-3 external variables
Access local variables of function blocks  — 
Tags - primitive types
Tags - Any Bit (e.g. var. %X1)  — 
Tags - Array  — 
Tags - Struct  — 
Tags - Array of Struct  — 
Tags - Local function block variables  —   — 

Feature PC Worx Engineer 7.2.x PLCnext Engineer 2019.0 LTS PLCnext Engineer 2019.3 PLCnext Engineer 2019.6
Supported GSDML Profile >= 2.2 2.2 - 2.34 2.2 - 2.34 2.2 - 2.35
Scan for Profinet devices
Global Profinet interface table
(all interface settings in one table)
 — 
MRP configurator)  —   —   — 

Feature PC Worx Engineer 7.2.x PLCnext Engineer 2019.0 LTS PLCnext Engineer 2019.3 PLCnext Engineer 2019.6
Support for Axioline local bus
Scan for Axioline devices  —   —   —   — 

Only in combination with AXC F IL ADAPT (Part no. 1020304) at an AXC F xxxx control !

Feature PC Worx Engineer 7.2.x PLCnext Engineer 2019.0 LTS PLCnext Engineer 2019.3 PLCnext Engineer 2019.6
Supported of Inline local bus  — 

Only in combination with AXC F XT ETH 1TX (Part no. 2403115)

Feature PC Worx Engineer 7.2.x PLCnext Engineer 2019.0 LTS PLCnext Engineer 2019.3 PLCnext Engineer 2019.6
Network configuration view  — 

Feature PC Worx Engineer 7.2.x PLCnext Engineer 2019.0 LTS PLCnext Engineer 2019.3 PLCnext Engineer 2019.6
OPC UA Security certification management
OPC UA Data Access configuration view
OPC UA Historical configuration view  —   —   —   — 

Feature PC Worx Engineer 7.2.x PLCnext Engineer 2019.0 LTS PLCnext Engineer 2019.3 PLCnext Engineer 2019.6
Logic analyzer  —    ✔*   ✔*
Watchwindow
Breakpoints
Execution values -
look at every online value
in your code, any time!
Debug in functions and methods  — 

* Supported only for IEC 61131-3 variables


First implementation in PLCnext Engineer 2019.0 LTS

Feature PLCnext Engineer 2019.0 LTS PLCnext Engineer 2019.3 PLCnext Engineer 2019.6
View Simulink® models
Drill down into submodels
Online values for GDS inports and outports
Multirate models  —   — 

Feature PC Worx Engineer 7.2.x PLCnext Engineer 2019.0 LTS PLCnext Engineer 2019.3 PLCnext Engineer 2019.6
User authentication -
PLC access
User authentication -
Change password
 — 
View security certificates of PLC  — 
Login template for web visualisation  —   — 
Remembering user credentials  —   —   — 

Feature PC Worx Engineer 7.2.x PLCnext Engineer 2019.0 LTS PLCnext Engineer 2019.3 PLCnext Engineer 2019.6
Network scan for
compatible controllers
PLCopen XML import from PC Worx 6
Device replacement - keeps data of all existing projects  —   — 
Safety Device replacement - keeps data of all existing projects  —   —   — 
AutomationML - APC (Automation Project Configuration)  —   — 
Project statistic overview - (consumptions and limits)  — 
Native support of 64 bit Operation Systems (Windows 7/10)
(32 bit systems are not longer supported)
 — 
Download sources with libraries  —   —   — 
Translation Management (comments and strings)  —   —   —   —