At the moment I try to implement the new AXL F IOL8 2H - 1027843.

I use the 2019.3 FW and SW version.

On the website I downloaded the FDCML3 file for import. It is included in the Components Area. It seems that this type is restricted for use directly on the Axioline-bus behind the Controller. There was some communication that it could only be used behind a PN BK. This module type is not included in the component area 'Axioline F Profinet'. A newer FDCML3 for the 2701815 can't be found also. How to implement the 1027843 behind the PN BK 2701815?

Second remark.

If I choose to configure the AXL F IOL8 2H behind the Controller on Axioline-bus you should use for Acyclic communication the IOL_Basic Function block and the AsynCom_AXL function block from the AsynCom_6 library. It seems that the IOL_Basic communication block doesn't work properly because I get the wDiagCode 16#C100 wAddDiagCode 16#00000000. It suggested that there is a timeout on Profinet. That doesn't make sense because I use it behind the controller and I have no PN communication.
How to solve this problem.

 

peterdallmann Accepted Answer Pending Moderation
0
Votes
Undo

I can send you a demo project for both application - direct on the controller and on a BK.

  1. more than a month ago
  2. PLCnext Engineer
  3. # 1
bram oostenbrug Accepted Answer Pending Moderation
0
Votes
Undo

Okay. If you have, I would be very happy.

Could you upload it to the Forum?

tnx

 

  1. more than a month ago
  2. PLCnext Engineer
  3. # 2
peterdallmann Accepted Answer Pending Moderation
0
Votes
Undo

I will upload it to the forum today but not later as tomorrow.

Peter Paul

  1. more than a month ago
  2. PLCnext Engineer
  3. # 3
peterdallmann Accepted Answer Pending Moderation
0
Votes
Undo

It is not possible to upload a zip file to the forum. e-mail?

Peter Paul

  1. more than a month ago
  2. PLCnext Engineer
  3. # 4
Manfred Masthoff Accepted Answer Pending Moderation
0
Votes
Undo

Same here. I try to get valid Data from the module, but get nothing. Is it possible to rename the Examples to .pdf and upload them?

I would be very happy if I could get a concrete example.

Gruß, Manfred

  1. more than a month ago
  2. PLCnext Engineer
  3. # 5
  • Page :
  • 1


There are no replies made for this post yet.
However, you are not allowed to reply to this post.